29 CFR 1910.38

OSHA 1910.38 Emergency Action Plan Requirements

Officially titled Emergency action plans. in 29 CFR 1910.38.

By ShieldSphere. Updated .

Short answer

OSHA 1910.38 sets the minimum contents of an emergency action plan whenever another Part 1910 standard requires one. The plan must be written, kept at the workplace and available to employees, though employers with 10 or fewer employees may communicate it orally. It must cover reporting emergencies, evacuation and exit route assignments, critical operations, employee accounting, rescue and medical duties, and contacts. Employers also need an employee alarm system, trained evacuation helpers and plan reviews with each employee.

What 1910.38 requires

The standard is short, but every part of it turns into real work at a facility. It tells you what an emergency action plan must contain, how it must be kept, how employees are warned, who helps during an evacuation, and when the plan has to be walked through with people.

A written plan kept where employees can see it

The plan must be in writing, kept in the workplace, and available to employees for review, 1910.38(b). A binder in a locked office or a file only managers can open does not meet the intent of availability. Employees should be able to read the plan without asking for special permission.

Six minimum elements of the plan

Paragraph 1910.38(c) lists what the plan must include at a minimum. Each element is a procedure or a name, and each one should match how your site actually operates.

  1. Procedures for reporting a fire or other emergency, 1910.38(c)(1).
  2. Procedures for emergency evacuation, including the type of evacuation and exit route assignments, 1910.38(c)(2).
  3. Procedures for employees who remain to operate critical plant operations before they evacuate, 1910.38(c)(3).
  4. Procedures to account for all employees after evacuation, 1910.38(c)(4).
  5. Procedures for employees performing rescue or medical duties, 1910.38(c)(5).
  6. The name or job title of every employee who may be contacted for more information about the plan or an explanation of duties under it, 1910.38(c)(6).

Type of evacuation matters because not every emergency calls for the same response. A fire may call for full building evacuation, while other events may call for a partial evacuation or sheltering in place. Your plan should say which response applies to which kind of event, and which exit route each work area uses.

An employee alarm system with distinct signals

You must have and maintain an employee alarm system, 1910.38(d). The system must use a distinctive signal for each purpose and must also comply with the separate employee alarm system standard that 1910.38(d) references. If one tone means evacuate and another means shelter, employees need to be able to tell them apart without guessing.

Designated and trained evacuation helpers

You must designate and train employees to assist in a safe and orderly evacuation of other employees, 1910.38(e). These are often called floor wardens or evacuation coordinators. The rule does not set a ratio or a training format, so you decide how many helpers you need based on your layout, shifts and headcount.

Reviewing the plan with each employee

You must review the plan with each employee it covers at three points under 1910.38(f). The first is when the plan is developed or the employee is first assigned to a job, 1910.38(f)(1). The second is when the employee's responsibilities under the plan change, 1910.38(f)(2). The third is whenever the plan itself is changed, 1910.38(f)(3).

Who 1910.38 applies to

This section does not create a stand-alone duty for every employer. Under 1910.38(a), an employer must have an emergency action plan whenever an OSHA standard in Part 1910 requires one, and the requirements in this section then apply to each such plan. In other words, 1910.38 is the rulebook for the plan, and other standards are the trigger.

In practice, that means the first step is to look at the standards that apply to your operations and see whether any of them call for an emergency action plan. Many general industry employers find that at least one does, so most facilities end up maintaining a plan. Even where no standard triggers the requirement, a plan built to this structure is a sound practice for any workplace.

Once a plan is required, it covers the employees at that workplace. The review duty in 1910.38(f) applies to each employee covered by the plan, including employees initially assigned to a job and anyone whose responsibilities under the plan change. The written plan must be kept in the workplace and available to employees for review, 1910.38(b). If you run several sites, it is good practice to fit each site's plan to its own building, exits, alarms and staffing.

Exemptions and exceptions

The standard contains one exception. An employer with 10 or fewer employees may communicate the plan orally to employees instead of putting it in writing, 1910.38(b).

This option changes only the format of the plan. It does not remove any of the content. A small employer communicating the plan orally still needs every minimum element listed in 1910.38(c) and an employee alarm system under 1910.38(d). It also still needs designated and trained evacuation helpers under 1910.38(e) and must review the plan with employees at the times listed in 1910.38(f).

As a practical matter, many small employers still keep a one-page written summary. It makes oral reviews consistent and gives you something to show that the plan exists if your headcount grows past 10.

What a compliant emergency action plan looks like in practice

A workable plan is specific to the building and the people in it. Generic templates are a starting point, but the plan only helps if it names real exits, real assembly points and real people. A strong plan usually includes the following pieces.

  • Reporting steps: how to pull an alarm, who to call, what number to dial, and what information to give.
  • Evacuation maps posted by work area that show primary and secondary exit routes and the assembly point.
  • A clear statement of which events trigger full evacuation, partial evacuation or shelter in place.
  • A short list of critical operations, such as shutting down a process or isolating a utility, with the job titles assigned to them and the point at which they must leave.
  • An accounting method, such as a sign-in sheet, badge roster or headcount by supervisor, plus a plan for visitors and contractors.
  • Rescue and medical roles, if any employees perform them, and a statement that all other employees evacuate and do not attempt rescue.
  • A contact list by name or job title for questions about the plan.

Roles should cover every shift. A warden who works days does not help a night crew, so assign backups and note who covers weekends and overtime. Keep a simple record of who was designated as an evacuation helper, what training they received and when, and when each employee had the plan reviewed with them. The standard does not prescribe these records, but they are the easiest way to show that the reviews in 1910.38(f) actually happened.

Drills are not required by this section, but they are the most reliable way to find gaps such as blocked routes, alarms that cannot be heard in loud areas, or a headcount process that takes too long. Many employers run them at least once a year and update the plan from what they learn. Remember that changing the plan triggers a new review with covered employees.

Common mistakes and frequently cited items

Most problems with emergency action plans come from plans that exist on paper but do not match the workplace. These are the gaps that show up most often when plans are checked against the requirements.

  • Missing elements. Plans often cover evacuation but leave out employee accounting, critical operations or rescue and medical duties, all of which are required minimum elements under 1910.38(c).
  • Vague evacuation procedures. A plan that says evacuate the building without stating the type of evacuation or assigning exit routes falls short of 1910.38(c)(2).
  • Outdated contacts. The plan names someone who left the company, so the contact requirement in 1910.38(c)(6) is no longer met in practice. Using job titles instead of names reduces this problem.
  • A plan nobody can find. Keeping the plan off site or locked away conflicts with the requirement that it be kept in the workplace and available to employees, 1910.38(b).
  • Alarms that sound alike. Using the same tone for different purposes defeats the distinctive signal requirement in 1910.38(d).
  • No designated helpers, or helpers who were named but never trained, which falls short of 1910.38(e).
  • Skipped reviews. New hires start work without a plan review, or the plan is revised and employees are never told, contrary to 1910.38(f)(1) and 1910.38(f)(3).
  • Misreading the small employer option as an exemption from the plan itself rather than from the written format.

Regulatory text

Short excerpts quoted exactly from 29 CFR 1910.38 as published in the eCFR. Read the full section for everything it requires.

1910.38(b)

This sets the format and availability of the plan and the only exception in the standard.

An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees.
1910.38(c)(2)

Evacuation procedures must go beyond a general instruction to leave and assign exit routes.

(2) Procedures for emergency evacuation, including type of evacuation and exit route assignments;
1910.38(c)(4)

Accounting for everyone after evacuation is a required element that plans often leave out.

(4) Procedures to account for all employees after evacuation;
1910.38(d)

The alarm system has to exist, be maintained and give employees signals they can tell apart.

An employer must have and maintain an employee alarm system. The employee alarm system must use a distinctive signal for each purpose and comply with the requirements in § 1910.165.
1910.38(e)

Evacuation helpers must be both designated and trained, not simply named.

An employer must designate and train employees to assist in a safe and orderly evacuation of other employees.
1910.38(f)

Plan reviews are owed to each covered employee, not just to supervisors or wardens.

An employer must review the emergency action plan with each employee covered by the plan:

Frequently asked questions

Does every employer need an emergency action plan under OSHA 1910.38?

Not automatically. Under 1910.38(a), an employer must have an emergency action plan whenever an OSHA standard in Part 1910 requires one, and 1910.38 then sets the requirements for that plan. Check the standards that apply to your operations to see whether one triggers the duty. Many facilities do have at least one trigger, and a plan built to this structure is good practice even where none applies.

Does an emergency action plan have to be written?

Generally yes. The plan must be in writing, kept in the workplace and available to employees for review, 1910.38(b). An employer with 10 or fewer employees may communicate the plan orally instead, under the same paragraph. The oral option changes only the format, so the plan still needs every minimum element and the other requirements of the section still apply.

What must an emergency action plan include?

At a minimum, 1910.38(c) requires procedures for reporting a fire or other emergency, procedures for evacuation including the type of evacuation and exit route assignments, procedures for employees who stay to run critical operations before they evacuate, procedures to account for all employees after evacuation, procedures for employees performing rescue or medical duties, and the name or job title of contacts for questions about the plan.

When must an emergency action plan be reviewed with employees?

The plan must be reviewed with each covered employee when the plan is developed or the employee is first assigned to a job, 1910.38(f)(1), when the employee's responsibilities under the plan change, 1910.38(f)(2), and when the plan is changed, 1910.38(f)(3). The section does not set a fixed calendar interval, but many employers add a periodic refresher or drill as a practical step.

Does OSHA 1910.38 require evacuation drills?

This section does not state a drill requirement. It does require that you designate and train employees to assist in a safe and orderly evacuation, 1910.38(e), and that you review the plan with employees at set points, 1910.38(f). Drills are a practical way to confirm that routes, alarms and headcount procedures work, and many employers use them to test and improve the plan.

What alarm system does 1910.38 require?

You must have and maintain an employee alarm system, 1910.38(d). The system must use a distinctive signal for each purpose and must also comply with the separate employee alarm system standard referenced in that paragraph. If your site uses different signals for evacuation and shelter in place, employees must be able to tell them apart, including in noisy work areas.

Key takeaways

  • 1910.38 sets the contents of an emergency action plan whenever another Part 1910 standard requires one.
  • The plan must be written, kept at the workplace and available to employees, except employers with 10 or fewer employees may communicate it orally.
  • Six minimum elements cover reporting, evacuation and exit routes, critical operations, employee accounting, rescue and medical duties, and contacts.
  • You need a maintained employee alarm system with a distinctive signal for each purpose.
  • Evacuation helpers must be designated and trained.
  • Review the plan with each employee at initial assignment, when their duties change and whenever the plan changes.

Sources

Find hazards before an inspector does

Upload a photo of your workplace and the AI Hazard Scanner flags visible hazards against the OSHA standards that apply to your site. Your first scan is free, no account required.

Find hazards before an inspector does

Last reviewed against the eCFR on November 10, 2026.

How these pages are produced and checked